Fire Sprinkler System | Fire Fighting Sprinkler | HD Fire Protect https://www.hdfire.com/products-solutions/sprinklers-accessories/ Fri, 19 Sep 2025 15:07:47 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.3 https://www.hdfire.com/wp-content/uploads/2025/04/cropped-hdfirelogo-32x32.png Fire Sprinkler System | Fire Fighting Sprinkler | HD Fire Protect https://www.hdfire.com/products-solutions/sprinklers-accessories/ 32 32 Pendent Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/pendent-sprinklers/ Wed, 05 Jun 2024 10:38:06 +0000 https://www.hdfire.com/?post_type=product&p=15922 Pendent mounting Standard and quick response with standard coverage Temperature rating : 57°, 68°, 79°& 93°C K-factor: 5.6 (80) Element: Glass bulb Occupancy Type: Light Hazard, Ordinary Hazard, Extra Hazard Thread Size: 1/2″ BSPT Max Pressure: 175 psi (12 bar) Brass, Chrome or White (RAL 9010), Custom colour shade available on request Sprinkler Wrench: Model

The post Pendent Sprinklers appeared first on hdfire.

]]>
  • Pendent mounting
  • Standard and quick response with standard coverage
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor: 5.6 (80)
  • Element: Glass bulb
  • Occupancy Type: Light Hazard, Ordinary Hazard, Extra Hazard
  • Thread Size: 1/2″ BSPT
  • Max Pressure: 175 psi (12 bar)
  • Brass, Chrome or White (RAL 9010), Custom colour shade available on request
  • Sprinkler Wrench: Model SP-M
  • Approvals: UL Listed and FM Approved (Refer to the catalogue for details)
  • The post Pendent Sprinklers appeared first on hdfire.

    ]]>
    Upright Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/upright-sprinklers/ Wed, 05 Jun 2024 10:38:07 +0000 https://www.hdfire.com/?post_type=product&p=15924 Upright mounting Standard and quick response with standard coverage Temperature rating : 57°, 68°, 79°& 93°C K-factor: 5.6 (80) Element: Glass bulb Occupancy Type: Light Hazard, Ordinary Hazard, Extra Hazard Thread Size: 1/2″ BSPT Max Pressure: 175 psi (12 bar) Brass, Chrome or White (RAL 9010), Custom colour shade available on request Sprinkler Wrench: Model

    The post Upright Sprinklers appeared first on hdfire.

    ]]>
  • Upright mounting
  • Standard and quick response with standard coverage
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor: 5.6 (80)
  • Element: Glass bulb
  • Occupancy Type: Light Hazard, Ordinary Hazard, Extra Hazard
  • Thread Size: 1/2″ BSPT
  • Max Pressure: 175 psi (12 bar)
  • Brass, Chrome or White (RAL 9010), Custom colour shade available on request
  • Sprinkler Wrench: Model SP-M
  • Approvals: UL Listed and FM Approved (Refer to the catalogue for details)
  • FAQ

    What is the difference between upright sprinkler and pendent sprinkler?

    Upright sprinklers face upward and spray water down, ideal for open ceilings and obstructions. Pendent sprinklers hang down, suited for finished ceilings.

    What is an upright type sprinkler?

    An upright sprinkler is mounted above the pipe with the deflector facing upward, spraying water downward to cover obstructed areas.

    What are the three types of sprinklers?

    Upright, Pendent, and Sidewall sprinklers.

    What are the benefits of upright sprinklers?
    • Best for warehouses and industrial spaces
    • Work well around obstructions
    • Easy to install above pipes
    • Available in multiple finishes and response types

    Specifications – Upright Sprinkler

    Parameter Details
    Mounting
    Upright
    Response
    Standard and Quick Response (Standard Coverage)
    Temperature Rating
    57°C, 68°C, 79°C & 93°C
    K-Factor
    5.6 (80)
    Element
    Glass Bulb
    Occupancy Type
    Light Hazard, Ordinary Hazard, Extra Hazard
    Thread Size
    1/2″ BSPT
    Max. Pressure
    175 psi (12 bar)
    Finishes
    Brass, Chrome, White (RAL 9010), Custom Colours on Request
    Sprinkler Wrench
    Model SP-M
    Approvals
    UL Listed & FM Approved (Refer to catalogue for details)

    The post Upright Sprinklers appeared first on hdfire.

    ]]>
    Horizontal Sidewall Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/horizontal-sidewall-sprinklers/ Wed, 05 Jun 2024 10:57:10 +0000 https://www.hdfire.com/?post_type=product&p=15930 Standard and quick response with standard coverage Horizontal Sidewall mounting Temperature rating : 68°, 79°& 93°C K-factor 5.6 and 4.2 Brass, Chrome or White/ custom colour finish UL Listed and FM Approved

    The post Horizontal Sidewall Sprinklers appeared first on hdfire.

    ]]>
  • Standard and quick response with standard coverage
  • Horizontal Sidewall mounting
  • Temperature rating : 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom colour finish
  • UL Listed and FM Approved
  • The post Horizontal Sidewall Sprinklers appeared first on hdfire.

    ]]>
    HSW – Extended Coverage, Quick Response Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/hsw-extended-coverage-quick-response-sprinklers/ Wed, 05 Jun 2024 10:38:07 +0000 https://www.hdfire.com/?post_type=product&p=15923 Quick response with Extended coverage Horizontal Sidewall Mounting Temperature rating : 57°, 68°, 79° & 93°C K-factor 5.6 and 8.0 Chrome finish UL Listed

    The post HSW – Extended Coverage, Quick Response Sprinklers appeared first on hdfire.

    ]]>
  • Quick response with Extended coverage
  • Horizontal Sidewall Mounting
  • Temperature rating : 57°, 68°, 79° & 93°C
  • K-factor 5.6 and 8.0
  • Chrome finish
  • UL Listed
  • The post HSW – Extended Coverage, Quick Response Sprinklers appeared first on hdfire.

    ]]>
    Vertical Sidewall Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/vertical-sidewall-sprinklers/ Wed, 05 Jun 2024 11:02:34 +0000 https://www.hdfire.com/?post_type=product&p=15938 Standard response with 5mm glass bulb and quick response with 3mm glass blub Vertical Sidewall mounting Temperature rating : 68°, 57°C K-factor 5.6 US (80 metric) Chrome plated finish UL Listed

    The post Vertical Sidewall Sprinklers appeared first on hdfire.

    ]]>
  • Standard response with 5mm glass bulb and quick response with 3mm glass blub
  • Vertical Sidewall mounting
  • Temperature rating : 68°, 57°C
  • K-factor 5.6 US (80 metric)
  • Chrome plated finish
  • UL Listed
  • The post Vertical Sidewall Sprinklers appeared first on hdfire.

    ]]>
    Concealed Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/concealed-sprinklers/ Wed, 05 Jun 2024 10:57:10 +0000 https://www.hdfire.com/?post_type=product&p=15931 Standard and Quick Response Brass Concealed Sprinkler with White or Chrome finish Cover Plate Temperature rating : 57°C & 68°C for Sprinkler bulb & 57°C for Cover Plate 79°C & 93°C for Sprinkler bulb & 68°C (155°F) for Cover Plate K-factor 5.6 UL Listed

    The post Concealed Sprinklers appeared first on hdfire.

    ]]>
  • Standard and Quick Response
  • Brass Concealed Sprinkler with White or Chrome finish Cover Plate
  • Temperature rating :
  • 57°C & 68°C for Sprinkler bulb & 57°C for Cover Plate
  • 79°C & 93°C for Sprinkler bulb & 68°C (155°F) for Cover Plate
  • K-factor 5.6
  • UL Listed
  • The post Concealed Sprinklers appeared first on hdfire.

    ]]>
    Conventional Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/conventional-sprinklers/ Wed, 05 Jun 2024 10:57:11 +0000 https://www.hdfire.com/?post_type=product&p=15932 Standard and quick response with standard coverage Pendent, recessed pendent & upright mounting Temperature rating : 57°, 68°, 79°& 93°C K-factor 5.6 Brass or Chrome finish UL Listed Note: NFPA permits the use of “Old Style/Conventional Sprinklers” where special construction features require unique water distribution

    The post Conventional Sprinklers appeared first on hdfire.

    ]]>
  • Standard and quick response with standard coverage
  • Pendent, recessed pendent & upright mounting
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor 5.6
  • Brass or Chrome finish
  • UL Listed
  • Note: NFPA permits the use of “Old Style/Conventional Sprinklers” where special construction features require unique water distribution
  • The post Conventional Sprinklers appeared first on hdfire.

    ]]>
    Recessed Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/recessed-sprinklers/ Wed, 05 Jun 2024 11:02:34 +0000 https://www.hdfire.com/?post_type=product&p=15939 Recessed sprinkler consists of sprinkler with escutcheon plate, also known as rosette plate Recessed sprinklers are commonly used in case of finished ceilings and walls Suitable for Pendent mounting White, chrome or custom colour finish UL Listed and FM Approved

    The post Recessed Sprinklers appeared first on hdfire.

    ]]>
  • Recessed sprinkler consists of sprinkler with escutcheon plate, also known as rosette plate
  • Recessed sprinklers are commonly used in case of finished ceilings and walls
  • Suitable for Pendent mounting
  • White, chrome or custom colour finish
  • UL Listed and FM Approved
  • The post Recessed Sprinklers appeared first on hdfire.

    ]]>
    Pendent, Upright, Recessed K-8 Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/pendent-upright-recessed-k-8-sprinklers/ Wed, 05 Jun 2024 11:02:35 +0000 https://www.hdfire.com/?post_type=product&p=15940 Standard and Quick Response with Standard Coverage Pendent & Upright Mounting Recessed Pendent Mounting K-factor 8 (115) ¾” connection Temperature rating: 57°, 68° , 79° & 93° C Brass & Chrome finish or custom painted UL Listed

    The post Pendent, Upright, Recessed K-8 Sprinklers appeared first on hdfire.

    ]]>
  • Standard and Quick Response with Standard Coverage
  • Pendent & Upright Mounting
  • Recessed Pendent Mounting
  • K-factor 8 (115)
  • ¾” connection
  • Temperature rating: 57°, 68° , 79° & 93° C
  • Brass & Chrome finish or custom painted
  • UL Listed
  • The post Pendent, Upright, Recessed K-8 Sprinklers appeared first on hdfire.

    ]]>
    Horizontal Sidewall K-8 Sprinklers https://www.hdfire.com/products-solutions/sprinklers-accessories/horizontal-sidewall-k-8-sprinklers/ Wed, 05 Jun 2024 11:02:36 +0000 https://www.hdfire.com/?post_type=product&p=15941 Standard and Quick Response with Standard Coverage Horizontal Sidewall Mounting Recessed Horizontal Sidewall Mounting K-factor 8 (115) ¾” connection Temperature rating: 57°, 68° , 79° & 93° C Brass & Chrome finish or custom painted UL Listed

    The post Horizontal Sidewall K-8 Sprinklers appeared first on hdfire.

    ]]>
  • Standard and Quick Response with Standard Coverage
  • Horizontal Sidewall Mounting
  • Recessed Horizontal Sidewall Mounting
  • K-factor 8 (115)
  • ¾” connection
  • Temperature rating: 57°, 68° , 79° & 93° C
  • Brass & Chrome finish or custom painted
  • UL Listed
  • The post Horizontal Sidewall K-8 Sprinklers appeared first on hdfire.

    ]]>